The 36,000 BTU Under/Floor Ceiling Split from Green Air-Conditioning is best suited for home, office and industrial use. This aircon will work optimal in rooms and areas with a floor size of up to 60m². Our franchises, agents and dealers are all highly trained professionals and will also be able to assist you with the installation.
Feel free to request a quote or contact us for expert advise.
Indoor Model | CM-U36NI-I | ||
Electric Parameter | |||
Power Supply | Indoor | V-ph-Hz | 220-240/1/50 |
Outdoor | V-ph-Hz | 220-240/1/50 | |
Input Consumption | Max | W | 4,800 |
Input Current | Max | A | 24.0 |
Cooling | |||
Capacity | Nominal | Btu/h | 33,096 |
W | 9,700 | ||
Min - Max | W | N/A | |
Input | Nominal | W | 3,130 |
Current | A | 14.2 | |
EER | W/W | 3.10 | |
Heating | |||
Capacity | Nominal | Btu/h | 35,485 |
W | 10,400 | ||
Min - Max | W | N/A | |
Input | Nominal | W | 2,880 |
Current | A | 13.8 | |
COP | W/W | 3.61 | |
Indoor Fan Motor | |||
Model | Y7S423B212 | ||
Quantity | 1 | ||
Input | W | 229.0 | |
Capacitor | μF | 8.0 | |
Speed (Hi / Medium / Low) | r/min | 1,260 / 1,130 / 1,000 | |
Indoor Coil | |||
Number of Rows | 3 | ||
Tube Pitch (a) x Row Pitch (b) | mm | 21 x 13.6 | |
Fin Spacing | mm | 1.5 | |
Fin Type | Hydrophilic Aluminium | ||
Tube Outside Diameter & Type | mm | Φ7.0, Innergroove Tube | |
Coil Length x Height x Width | mm | 930 x 336 x 40.8 | |
Number of Circuits | 3 | ||
Indoor Unit | |||
Dimension | W x H x D | mm | 1,285 x 230 x 680 |
Packaging | W x H x D | mm | 1,400 x 350 x 820 |
Weight | Net / Gross | kg | 40.0 / 47.0 |
Air Volume | Hi / Medium / Low | m³/h | 1,700 / 1,650 / 1,500 |
CFM | 1,000 / 971 / 882 | ||
Sound Level (SPL) | db(A) | 54 / 52 / 50 | |
Sound Level (PWL) | Hi | db(A) | N/A |
External Static Pressure | Rated | Pa | NA |
Before Shipment | Pa | NA | |
Range | Pa | NA | |
Controller | Type | Wireless | |
Model |
J1-06 (E) L1-12 (E) R2-01 (E) |
||
Drainage Water Pipe Diameter | mm | De25 | |
Drain Pump | N/A | ||
Air Filter | Standard | ||
Throttle Type | N/A | ||
Booster Heater | kW | N/A | |
Design Pressure | H/L | MPa | 4.4 / 1.6 |
Room Temperature | |||
Setting Temperature Range | Cooling | ℃ | 16~30 |
Heating | ℃ | 16~30 | |
Outdoor Model | CM-U36NI-O | ||
Compressor | |||
Model | ATH356MV-C9EUA | ||
Type | Rotary | ||
Brand | Highly | ||
Capacity | Btu/h | 29,172 | |
Input | W | 2,950 | |
Rated Current (RLA) | A | 14.10 | |
Locked Rotor Amp (LRA) | A | 67 | |
Thermal Protector Position | Internal | ||
Capacitor | μF | 55 | |
Refigerant Oil | Model | α68HES-H | |
Amount | ml | 880 | |
Outdoor Fan Motor | |||
Model | Y6S696D511 | ||
Quantity | 1 | ||
Input | W | 160 | |
Capacitor | μF | 6 | |
Speed | r/min | 880 / 740 / 660 | |
Outdoor Coil | |||
Number of Rows | 2 | ||
Tube Pitch (a) x Row Pitch (b) | mm | 21 x 18.19 | |
Fin Spacing | mm | 1.6 | |
Fin Type | Hydrophilic Aluminium | ||
Tube Outside Diameter & Type | mm | Φ7.0, Innergroove Tube | |
Coil Length x Height x Width | mm | 970 x 756 x 36.38 | |
Number of Circuits | 5 | ||
Outdoor Unit | |||
Dimension | W x H x D | mm | 885 x 795 x 366 |
Packaging | W x H x D | mm | 1,050 x 890 x 500 |
Weight | Net / Gross | kg | 65 / 69 |
Air Volume | Hi | m³/h | |
Sound Level (SPL) | db(A) | 62 | |
Sound Level (PWL) | db(A) | N/A | |
Refrigerant | Type | R410A | |
Amount | kg | 2.15 | |
TCO2Eq | 4.489 | ||
GWP | 2,088 | ||
Throttle Type | Capillary | ||
Design Pressure | H/L | MPa | 4.4 / 1.6 |
Refrigerant Piping | |||
Liquid / Gas | mm (inch) | Φ9.52 / Φ19.05 (3/8" / 3/4") | |
Pipe Length | Max | m | 40 |
Height Difference | Max (OD Lower) | m | 20 |
Max (OD Heigher) | m | 20 | |
ADD Refrigerant Amount | g/m | 35 | |
Pipe Length For Additional Refrigerant | m | 5 | |
Operating Range | |||
Cooling | ℃ | -15~43 | |
Heating | ℃ | -10~24 |