The 60000 BTU Under/Floor Ceiling Inverter Split from Green Air-Conditioning is best suited for home, office and industrial use. This aircon will work optimal in rooms and areas with a floor size of up to 100m². Our franchises, agents and dealers are all highly trained professionals and will also be able to assist you with the installation.
Feel free to request a quote or contact us for expert advise.
Type of Unit | UNDER/FLOOR CEILING INVERTER SPLIT | ||
---|---|---|---|
Model | UFCM-H60/5DR1C | ||
Indoor Power Supply | V~,Hz,Ph | 220~240/50/1 | |
Cooling | Capacity | Btu/h | 55000 |
Capacity | kW | 16.00 | |
Input | KW | 6.30 | |
Rated current | A | 10.80 | |
EER | W/W | 2.50 | |
SEER | W/W | - | |
Heating | Capacity | Btu/h | 58000 |
Capacity | KW | 17.00 | |
Input | KW | 5.80 | |
Rated current | A | 11.00 | |
COP | W/W | 2.90 | |
Indoor Fan Motor | Model | FP120D-ZL 310V | |
Brand | Wolong | ||
Output Power | W | 120 | |
Capacitor | uF | / | |
Speed (Hi/Med/Low) | r/min | 1280/1100/920 | |
Indoor Coil | Number of Rows | 3.0 | |
Tube Pitch (a) x Row Pitch (b) | mm | 20.5 x 12.7 | |
Fin Pitch | mm | 1.5 | |
Fin Type | Hydrophilic | ||
Tube Outside Dia and Type | mm | Φ7 Inner grooved | |
Coil length x height x width | mm | 1291 x 307 x 38.1 | |
Number of circuits | 7 | ||
Indoor Airflow (Hi/Mi/Lo) | m³/h | 2070/1770/1470 | |
CFM | 1240/1060/880 | ||
Indoor noise level | Power level (Hi/Mi/Lo) | dB(A) | 55/49/45 |
Indoor Unit | Dimension (W x D x H) Body | mm | 1600 x 690 x 235 |
Packaging (W x D x H) Body | mm | 1680 x 770 x 325 | |
Net/Gross weight Body | Kg | 41/45 | |
Panel | Kg | 5.7/8.3 | |
Refrigerant Piping | Liquid Side/Gas Side | mm | 9.52/19.05 (3/8"+3/4") |
Max. Refrigerant Pipe Length | m | 50 | |
Max. Difference In Level | m | 30 | |
Drainage Pipe | mm | R3/4in(DN20) | |
Operation Temperature | °C | 16~32 | |
Ambient Temperature | Cooling | °C | 5~48 |
Heating | °C | -15~24 | |
Application Area | m² | 64-107 | |
Connection Wiring | Power Wiring (Indoor) | mm² | 3 x 1.5 |
Signal Wiring | mm² | 2 x 0.2 | |
Wireless Remote Controller | YKR-K/001E | ||
Model | UFCM-H60/5DR1C | ||
Outdoor Power Supply | V~,Hz,Ph | 380~415/50/3 | |
Max.Input Consumption | W | 7500 | |
Max. Current | A | 11.05 | |
Cooling | Capacity | Btu/h | 55000 |
Capacity | Kw | 16.12 | |
Heating | Capacity | Btu/h | 63500 |
Capacity | kW | 18.61 | |
Compressor | Model | KTF400D66UMVA | |
Type | Rotary | ||
Brand | GMCC | ||
Frequency range | Hz | 12-120 | |
Capacity | W | 13100 | |
Input | W | 3465 | |
Rated current (RLA) | A | 6.65 | |
Refrigerant Oil | ml | 1400 | |
Outdoor Fan Motor | Model | CW85D | |
Brand | Xinjun | ||
Power Output x Fan Quantity | W | 85 x 2 | |
Speed | r/min | 770 | |
Capacitor | uF | 4 x 2 | |
Outdoor Coil | Number of rows | 2 | |
Tube Pitch (a) Test Row Pitch | mm | 22 x 19.05 | |
Fin Pitch | mm | 1.4 | |
Fin type | Hydrophilic Aluminum Fin | ||
Tube outside dia. and type | mm | Φ7 Inner grooved | |
Coil lenght x height x width | mm | 918 x 1276 x 38.1 | |
Number of circuits | 9 | ||
Air Flow Volume | m³h | 7000 | |
CFM | 3765 | ||
Outdoor noise level | Power level | dB(A) | 70 |
Pressure level | 60 | ||
Outdoor Unit | Dimension (W x D x H) | mm | 940 x 370 x 1325 |
Packaging (W x D x H) | mm | 1080 x 430 x 1440 | |
Net/Gross weight | Kg | 90/100 | |
Refrigerant | Type / Charged Volume | Kg | R410A/3.45 |
Design Pressure | MPa | 4.2 | |
Connecting Wiring | Power wiring | mm | 5 x 2.5 |
Signal wiring | mm | 2 x 0.2 | |
Refrigerant Piping | Liquid Side/Gas Side | mm | 9.52/19.05 (3/8" + 3/4") |
Max Pipe Length | m | 50 | |
Max Pipe Height | m | 30 | |
Drainage | mm | R3/4in(DN20) | |
Ambient Temp | Cooling | °C | -5~49 |
Heating | °C | -5~24 | |
Operation Temperature Range | °C | 16~32 | |
Application Area | m³ | 64-107 | |
Stuffing Quantity 20/40/40H | Unit | 27/55/55 |